Nano Science and Technology Institute - NSTI  
Nano Science and Technology Institute   Home | Subscribe | Site Map  
  ABOUT | COURSES | EVENTS | PUBLICATIONS | LEADERSHIP | OUTREACH | NEWS | PRESS | JOBS | Nanotechnology Solutions
px
px fade_top
Publications
Nanotech 2008 CDROM
Nanotech 2007 CDROM
Nanotech 2006 CDROM
Nanotech 2005 CDROM
Nanotech 2004 CDROM
3 CDROM Special Offer
Nanotech 2008 Vol. 1
Nanotech 2008 Vol. 2
Nanotech 2008 Vol. 3
Nanotech 2007 Vol. 1
Nanotech 2007 Vol. 2
Nanotech 2007 Vol. 3
Nanotech 2007 Vol. 4
Nanotech 2006 Vol. 1
Nanotech 2006 Vol. 2
Nanotech 2006 Vol. 3
Nanotech 2005 Vol. 1
Nanotech 2005 Vol. 2
Nanotech 2005 Vol. 3
WCM 2005
Nanotech 2004 Vol. 1
Nanotech 2004 Vol. 2
Nanotech 2004 Vol. 3
Nanotech 2003 Vol. 1
Nanotech 2003 Vol. 2
Nanotech 2003 Vol. 3
Nanotech 2002 Vol. 1
Nanotech 2002 Vol. 2
Nanotech 2001 Vol. 1
Nanotech 2001 Vol. 2
MSM 2000
MSM 99
MSM 98
Index of Authors
Index of Keywords
Index of Affiliations
Library Request Form
Shopping Cart
Order Form
 
Publications Publications
Nanotech 2007 Vol. 3
p
 
Technical Proceedings of the 2007 NSTI Nanotechnology Conference and Trade Show, Volume 3
Nanotech 2007 Vol. 3
Technical Proceedings of the 2007 NSTI Nanotechnology Conference and Trade Show, Volume 3
 
Chapter 5: Micro and Nano Fluidics Design and Simulation
 

Novel Electro Magnetic Micro Pump

Authors:M. Feldmann, S. Demming and S. Büttgenbach
Affilation:Institute for Microtechnology, DE
Pages:441 - 443
Keywords:micro pump, electro magnetic, PDMS, polymer magnets, micro coils, micro valve, plunger coil actuator
Abstract:The mergence of partial aspects and functional components of micro actuators and micro fluidic technology allows the development of complex micro systems. This enormous potential is shown in this article by the realization of an electro magnetic micro pump. The basic build-up consists of a polymer magnet integrated into a pump chamber of a fluidic PDMS device, which is located above a double layer micro coil. When applying a current, the polymer magnet performs a bidirectional movement, which results in a pumping effect by the two passive check valves. The valves, which consist of a membrane and lips pressing on a valve seat, can thus completely seal the fluid channel. The fluidic system for this novel micro pump was at first fabricated without the double layer spiral coil and successfully tested. In order to connect the valve seats based on SU-8 with the PDMS fluid chamber and valve lips, a special bonding process was developed. The next step is to combine the fluidic system with the electromagnetic part which is currently under investigation.