Nano Science and Technology Institute - NSTI  
Nano Science and Technology Institute   Home | Subscribe | Site Map  
  ABOUT | COURSES | EVENTS | PUBLICATIONS | LEADERSHIP | OUTREACH | NEWS | PRESS | JOBS | Nanotechnology Solutions
px
px fade_top
Publications
Nanotech 2008 CDROM
Nanotech 2007 CDROM
Nanotech 2006 CDROM
Nanotech 2005 CDROM
Nanotech 2004 CDROM
3 CDROM Special Offer
Nanotech 2008 Vol. 1
Nanotech 2008 Vol. 2
Nanotech 2008 Vol. 3
Nanotech 2007 Vol. 1
Nanotech 2007 Vol. 2
Nanotech 2007 Vol. 3
Nanotech 2007 Vol. 4
Nanotech 2006 Vol. 1
Nanotech 2006 Vol. 2
Nanotech 2006 Vol. 3
Nanotech 2005 Vol. 1
Nanotech 2005 Vol. 2
Nanotech 2005 Vol. 3
WCM 2005
Nanotech 2004 Vol. 1
Nanotech 2004 Vol. 2
Nanotech 2004 Vol. 3
Nanotech 2003 Vol. 1
Nanotech 2003 Vol. 2
Nanotech 2003 Vol. 3
Nanotech 2002 Vol. 1
Nanotech 2002 Vol. 2
Nanotech 2001 Vol. 1
Nanotech 2001 Vol. 2
MSM 2000
MSM 99
MSM 98
Index of Authors
Index of Keywords
Index of Affiliations
Library Request Form
Shopping Cart
Order Form
 
Publications Publications
Nanotech 2006 Vol. 2
p
 
Technical Proceedings of the 2006 NSTI Nanotechnology Conference and Trade Show, Volume 2
Nanotech 2006 Vol. 2
Technical Proceedings of the 2006 NSTI Nanotechnology Conference and Trade Show, Volume 2
 
Chapter 3: Bio Sensors and Diagnostics
 

Magnetic Devices for Ultra High Throughput Biological Analysis

Authors:T. Mitrelias, Z. Jiang, J. Llandro and J.A.C. Bland
Affilation:University of Cambridge, UK
Pages:256 - 259
Keywords:magnetic biosensors, microfluidic channel, integrated cell
Abstract:In this report we present an integrated microfluidic cell for detecting and sorting magnetic beads in solution. The cell has been developed for magnetic biosensing, which comprises both magnetoresistive sensors optimized for the detection of single 9 m ferromagnetic beads in suspension and electrodes to manipulate and sort the beads, integrated into a microfluidic channel. The suspended beads are moved along a 75x75 μm wide microfluidic channel patterned in SU8 over 10 μm diameter ring shaped sensors arranged in Wheatstone bridge, with two active elements in phase in the channel and two reference elements outside it. The device is designed to read out the real-time voltage signal as a bead perturbs an in-plane applied field in the vicinity of the active elements, changing their resistances and unbalancing the bridge by an amount proportional to the bead’s magnetic moment. Beads of different magnetic moments can thus be detected and sorted through a magnetostatic sorting gate into different branches of the microfluidic channel, using magnetic field gradients applied by the photolithography defined 120 nm thick Cu striplines carrying 0.2A DC. The cell is unique because it’s design facilitates the integration of magnetic sensors with the microfluidic channels and also because it has individually addressable sorting striplines that divert magnetic beads in flow by applying currents locally.
ISBN:0-9767985-7-3
Pages:893
Hardcopy:$185.00
 
Order:Mail/Fax Form
Special:3 CD Set — 15% off with Free Shipping
Up
Upcoming Events
Nanotech 2009
Cleantech 2009
BioNano 2009
TechConnect Summit
nanoPRwire™
nanoPRwire
News Headlines
nano World news
 
 
 
 
px
© Nano Science and Technology Institute     About NSTI | Terms of Use | Privacy Policy | Contact