Nano Science and Technology Institute - NSTI  
Nano Science and Technology Institute   Home | Subscribe | Site Map  
  ABOUT | COURSES | EVENTS | PUBLICATIONS | LEADERSHIP | OUTREACH | NEWS | PRESS | JOBS | Nanotechnology Solutions
px
px fade_top
Publications
Nanotech 2007 CDROM
Nanotech 2006 CDROM
Nanotech 2005 CDROM
Nanotech 2004 CDROM
3 CDROM Special Offer
Nanotech 2007 Vol. 1
Nanotech 2007 Vol. 2
Nanotech 2007 Vol. 3
Nanotech 2007 Vol. 4
Nanotech 2006 Vol. 1
Nanotech 2006 Vol. 2
Nanotech 2006 Vol. 3
Nanotech 2005 Vol. 1
Nanotech 2005 Vol. 2
Nanotech 2005 Vol. 3
WCM 2005
Nanotech 2004 Vol. 1
Nanotech 2004 Vol. 2
Nanotech 2004 Vol. 3
Nanotech 2003 Vol. 1
Nanotech 2003 Vol. 2
Nanotech 2003 Vol. 3
Nanotech 2002 Vol. 1
Nanotech 2002 Vol. 2
Nanotech 2001 Vol. 1
Nanotech 2001 Vol. 2
MSM 2000
MSM 99
MSM 98
Index of Authors
Index of Keywords
Index of Affiliations
Library Request Form
Shopping Cart
Order Form
 
Publications Publications
Nanotech 2004 Vol. 1
p
 
Technical Proceedings of the 2004 NSTI Nanotechnology Conference and Trade Show, Volume 1
Nanotech 2004 Vol. 1
Technical Proceedings of the 2004 NSTI Nanotechnology Conference and Trade Show, Volume 1
 
Chapter 6: Bio Micro Sensors and Systems
 

Potentiometric Biosensors Based on Silicon and Porous Silicon

Authors:I. Basu, R.V. Subramanian, A. Mathew, A. Chadha and E. Bhattacharya
Affilation:Indian Institute of Technology Madras, IN
Pages:224 - 227
Keywords:biosensor, EISCAP, triglyceride, urea, porous silicon
Abstract:Detection and estimation of Triglycerides and Urea are clinically important. We report fabrication of potentiometric biosensors based on silicon and porous silicon and estimation of triglycerides and urea based on enzymatic reactions. The sensor is an ElectrolyteInsulator-Semiconductor capacitor (EISCAP) that shows a shift in the measured CV with changes in the pH of the electrolyte. Many biological reactions, especially enzyme mediated ones, involve changes in the pH of the electrolyte and an EISCAP can be effectively used as a biosensor. We have earlier reported on an EISCAP sensor, where the semiconductor was porous silicon and the insulator was SiO2, for Tributyrin - a short chain triglyceride which produced butyric acid on hydrolysis in the presence of the enzyme lipase. Use of silicon nitride as the insulator has advantages over SiO2 since the nitride is stable in contrast to SiO2, which dissolves in basic solutions allowing for the possibility of detection extended to the basic range. The sensor with nitride as the insulator is calibrated for estimation of Tributyrin and Urea. Results are reported on both silicon and porous silicon as the semiconductor layer.
ISBN:0-9728422-7-6
Pages:521
Hardcopy:$150.00
Special:3 CD Set — 15% off with Free Shipping
 
Order:Mail/Fax Form
Up
Upcoming Events
Nanotech 2008
Cleantech 2008
BioNano 2008
TechConnect Summit
nanoPRwire™
nanoPRwire
News Headlines
nano World news
 
 
 
 
px
© Nano Science and Technology Institute     About NSTI | Terms of Use | Privacy Policy | Contact