Nano Science and Technology Institute - NSTI  
Nano Science and Technology Institute   Home | Subscribe | Site Map  
  ABOUT | COURSES | EVENTS | PUBLICATIONS | LEADERSHIP | OUTREACH | NEWS | PRESS | JOBS | Nanotechnology Solutions
px
px fade_top
Publications
Nanotech 2008 CDROM
Nanotech 2007 CDROM
Nanotech 2006 CDROM
Nanotech 2005 CDROM
Nanotech 2004 CDROM
3 CDROM Special Offer
Nanotech 2008 Vol. 1
Nanotech 2008 Vol. 2
Nanotech 2008 Vol. 3
Nanotech 2007 Vol. 1
Nanotech 2007 Vol. 2
Nanotech 2007 Vol. 3
Nanotech 2007 Vol. 4
Nanotech 2006 Vol. 1
Nanotech 2006 Vol. 2
Nanotech 2006 Vol. 3
Nanotech 2005 Vol. 1
Nanotech 2005 Vol. 2
Nanotech 2005 Vol. 3
WCM 2005
Nanotech 2004 Vol. 1
Nanotech 2004 Vol. 2
Nanotech 2004 Vol. 3
Nanotech 2003 Vol. 1
Nanotech 2003 Vol. 2
Nanotech 2003 Vol. 3
Nanotech 2002 Vol. 1
Nanotech 2002 Vol. 2
Nanotech 2001 Vol. 1
Nanotech 2001 Vol. 2
MSM 2000
MSM 99
MSM 98
Index of Authors
Index of Keywords
Index of Affiliations
Library Request Form
Shopping Cart
Order Form
 
Publications Publications
Nanotech 2003 Vol. 1
p
 
Technical Proceedings of the 2003 Nanotechnology Conference and Trade Show, Volume 1
Nanotech 2003 Vol. 1
Technical Proceedings of the 2003 Nanotechnology Conference and Trade Show, Volume 1
 
Chapter 4: Bio-Molecular Analysis and Characterization
 

PCR Micro-Voume Device for Detection of Nucleic Acids

Authors:P-A Auroux, P. Day, F. Niggli and A. Manz
Affilation:Kinderspital, CH
Pages:55 - 58
Keywords:micro-fluidics, DNA, PCR, lab-on-a-chip
Abstract:The polymerase chain reaction (PCR) is an enzyme-mediated nucleic acid amplifer process that is employed extensively throughout the medical and biological sciences. The technique has risen to acclaim largely through its exquisite sensitivity, but an inability to distinguish trace contaminants plus high operating costs greatly reduce its impact on further potential applications. Additionally, the process tends to diminish gene detection sensitivity within a highly heterogenous cell population, detection may be totally lost if even marginally diluted. A microfluidics device has intrinsic properties, particularly if multi-parallelised, can alleviate risk of contamination and also increases detection sensitivity of low copy number genes in complex cell populations, which we demonstrate utilizing a PCR amplifier device with shunting microfluidics. Our reactor consists of a microstructure constructed from SU-8, and sandwiched by PMMA. The proof of principle experiment was conducted with a modified glass capillary manufactured by Roche Diagnostics GmbH. Firstly PCR was performed without any optimization and the sample was then analyzed using an Agilent 2100 Bioanalyser. The specifically amplified product was determined to have a concentration of 0.36ng/uL. The analysis of positive controls gave a 6.1ng/uL average concentration, which means that our experiment had an efficiency of 6%. Further experiments will be needed in order to optimize the system.
PCR Micro-Voume Device for Detection of Nucleic AcidsView paper
ISBN:0-9728422-0-9
Pages:560
Hardcopy:$125.00
Special:3 CD Set — 15% off with Free Shipping
Up
Upcoming Events
Nanotech 2009
Cleantech 2009
BioNano 2009
TechConnect Summit
nanoPRwire™
nanoPRwire
News Headlines
nano World news
 
 
 
 
px
© Nano Science and Technology Institute     About NSTI | Terms of Use | Privacy Policy | Contact