Nano Science and Technology Institute - NSTI  
Nano Science and Technology Institute   Home | Subscribe | Site Map  
  ABOUT | COURSES | EVENTS | PUBLICATIONS | LEADERSHIP | OUTREACH | NEWS | PRESS | JOBS | Nanotechnology Solutions
px
px fade_top
Publications
Nanotech 2007 CDROM
Nanotech 2006 CDROM
Nanotech 2005 CDROM
Nanotech 2004 CDROM
3 CDROM Special Offer
Nanotech 2007 Vol. 1
Nanotech 2007 Vol. 2
Nanotech 2007 Vol. 3
Nanotech 2007 Vol. 4
Nanotech 2006 Vol. 1
Nanotech 2006 Vol. 2
Nanotech 2006 Vol. 3
Nanotech 2005 Vol. 1
Nanotech 2005 Vol. 2
Nanotech 2005 Vol. 3
WCM 2005
Nanotech 2004 Vol. 1
Nanotech 2004 Vol. 2
Nanotech 2004 Vol. 3
Nanotech 2003 Vol. 1
Nanotech 2003 Vol. 2
Nanotech 2003 Vol. 3
Nanotech 2002 Vol. 1
Nanotech 2002 Vol. 2
Nanotech 2001 Vol. 1
Nanotech 2001 Vol. 2
MSM 2000
MSM 99
MSM 98
Index of Authors
Index of Keywords
Index of Affiliations
Library Request Form
Shopping Cart
Order Form
 
Publications Publications
MSM 99
p
 
Technical Proceedings of the 1999 International Conference on Modeling and Simulation of Microsystems
MSM 99
Technical Proceedings of the 1999 International Conference on Modeling and Simulation of Microsystems
 
Chapter 16: Applications: Microfluidics
 

Microvalve Analysis: Wall Shear and Diffuser Effects

Authors:M. Carmona, S. Marco, J. Samitier, M.C. Acero, J.A. Plaza and J. Esteve
Affilation:University of Barcelona, Spain
Pages:554 - 557
Keywords:microvalve, finite element method, analytical modelling, microfluidic measurements
Abstract:This work deals with the analysis of silicon passive microvalves. The analysed microvalves consist of a circular central mass suspended by two flexible beams anchored on a pyrex substrate. The mechanical and fluidic analysis are first done by FEM (FLOTRAN) simulations, and afterwards the results are compared to an iterative analytical model, showing good agreement at low flow rates. In this model, we have taken into account viscous losses as well as inertial ones, usually neglected in model extraction and validation. A good fitting is achieved at high flow rates for a diminished inertial losses contribution. Measurements with air have been carried out in order to validate the proposed model.
Microvalve Analysis: Wall Shear and Diffuser EffectsView paper
ISBN:0-9666135-4-6
Pages:697
Special:3 CD Set — 15% off with Free Shipping
Up
Upcoming Events
Nanotech 2008
Cleantech 2008
BioNano 2008
TechConnect Summit
nanoPRwire™
nanoPRwire
News Headlines
nano World news
 
 
 
 
px
© Nano Science and Technology Institute     About NSTI | Terms of Use | Privacy Policy | Contact