Nano Science and Technology Institute - NSTI  
Nano Science and Technology Institute   Home | Subscribe | Site Map  
  ABOUT | COURSES | EVENTS | PUBLICATIONS | LEADERSHIP | OUTREACH | NEWS | PRESS | JOBS | Nanotechnology Solutions
px
px fade_top
Publications
Nanotech 2007 CDROM
Nanotech 2006 CDROM
Nanotech 2005 CDROM
Nanotech 2004 CDROM
3 CDROM Special Offer
Nanotech 2007 Vol. 1
Nanotech 2007 Vol. 2
Nanotech 2007 Vol. 3
Nanotech 2007 Vol. 4
Nanotech 2006 Vol. 1
Nanotech 2006 Vol. 2
Nanotech 2006 Vol. 3
Nanotech 2005 Vol. 1
Nanotech 2005 Vol. 2
Nanotech 2005 Vol. 3
WCM 2005
Nanotech 2004 Vol. 1
Nanotech 2004 Vol. 2
Nanotech 2004 Vol. 3
Nanotech 2003 Vol. 1
Nanotech 2003 Vol. 2
Nanotech 2003 Vol. 3
Nanotech 2002 Vol. 1
Nanotech 2002 Vol. 2
Nanotech 2001 Vol. 1
Nanotech 2001 Vol. 2
MSM 2000
MSM 99
MSM 98
Index of Authors
Index of Keywords
Index of Affiliations
Library Request Form
Shopping Cart
Order Form
 
Publications Publications
Nanotech 2002 Vol. 1
p
 
Technical Proceedings of the 2002 International Conference on Modeling and Simulation of Microsystems
Nanotech 2002 Vol. 1
Technical Proceedings of the 2002 International Conference on Modeling and Simulation of Microsystems
 
Chapter 5: MEMS Applications and Characterization
 

Comparative Studies of Novel Capacitive Transducers with Non-Planar Diaphragms

Authors:J. Chen, L. Liu and Z. Li
Affilation:Tsinghua University, China
Pages:238 - 241
Keywords:corrugation, FEA, couple-field analysis, capacitor, diaphragm
Abstract:Novel single-chip fabricated condenser structures with corrugated diaphragms for residual stress releasing have been proposed and simulated. An electrostatic-structural coupling FEM analysis has been performed to fully reveal the nonlinear relationship of output electrical signal with respect to input mechanical change. The influence of various nonlinear effects on the performance of transducers is investigated. Two typical corrugation layouts are studied. Numerical results have shown that the round structure was promising with its potential of high sensitivity, while the squared one was superior in the low-voltage applications. The ill effects of these variations can be reduced by delicate design and adjusting of corresponding processes.
Comparative Studies of Novel Capacitive Transducers with Non-Planar DiaphragmsView paper
ISBN:0-9708275-7-1
Pages:764
Special:3 CD Set — 15% off with Free Shipping
Up
Upcoming Events
Nanotech 2008
Cleantech 2008
BioNano 2008
TechConnect Summit
nanoPRwire™
nanoPRwire
News Headlines
nano World news
 
 
 
 
px
© Nano Science and Technology Institute     About NSTI | Terms of Use | Privacy Policy | Contact